flow sensors Search Results


95
Sensirion ag sli 0430 liquid flow meter
Sli 0430 Liquid Flow Meter, supplied by Sensirion ag, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/sli 0430 liquid flow meter/product/Sensirion ag
Average 95 stars, based on 1 article reviews
sli 0430 liquid flow meter - by Bioz Stars, 2026-06
95/100 stars
  Buy from Supplier

95
Elveflow Inc microfluidic flow sensor
Microfluidic Flow Sensor, supplied by Elveflow Inc, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microfluidic flow sensor/product/Elveflow Inc
Average 95 stars, based on 1 article reviews
microfluidic flow sensor - by Bioz Stars, 2026-06
95/100 stars
  Buy from Supplier

92
Elveflow Inc flow rate sensor
Flow Rate Sensor, supplied by Elveflow Inc, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/flow rate sensor/product/Elveflow Inc
Average 92 stars, based on 1 article reviews
flow rate sensor - by Bioz Stars, 2026-06
92/100 stars
  Buy from Supplier

94
Sensirion ag flow sensor
Flow Sensor, supplied by Sensirion ag, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/flow sensor/product/Sensirion ag
Average 94 stars, based on 1 article reviews
flow sensor - by Bioz Stars, 2026-06
94/100 stars
  Buy from Supplier

90
Millar Inc micromanometers and an electromagnetic flow velocity sensor millar instruments
Micromanometers And An Electromagnetic Flow Velocity Sensor Millar Instruments, supplied by Millar Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/micromanometers and an electromagnetic flow velocity sensor millar instruments/product/Millar Inc
Average 90 stars, based on 1 article reviews
micromanometers and an electromagnetic flow velocity sensor millar instruments - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
FLUIGENT Inc microheater-based flow sensors model s
Microheater Based Flow Sensors Model S, supplied by FLUIGENT Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microheater-based flow sensors model s/product/FLUIGENT Inc
Average 90 stars, based on 1 article reviews
microheater-based flow sensors model s - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
JENOPTIK Inc flow meter sensor setup
Flow Meter Sensor Setup, supplied by JENOPTIK Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/flow meter sensor setup/product/JENOPTIK Inc
Average 90 stars, based on 1 article reviews
flow meter sensor setup - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
SynDaver Labs flow sensor
Flow Sensor, supplied by SynDaver Labs, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/flow sensor/product/SynDaver Labs
Average 90 stars, based on 1 article reviews
flow sensor - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
National Institute of Standards and Technology flow sensor 347
Flow Sensor 347, supplied by National Institute of Standards and Technology, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/flow sensor 347/product/National Institute of Standards and Technology
Average 90 stars, based on 1 article reviews
flow sensor 347 - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Vernier Software flow rate sensor flobta
Flow Rate Sensor Flobta, supplied by Vernier Software, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/flow rate sensor flobta/product/Vernier Software
Average 90 stars, based on 1 article reviews
flow rate sensor flobta - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
PendoTECH single-use pressure sensor flow cells
Comparison of anion exchange media. Chromatograms from small-scale anion exchange experiments are shown. In all cases, solid lines indicate A 280 (left axis) and dashed lines indicate <t>conductivity</t> (right axis). A 260 data was also collected, with results paralleling the A 280 data, but is omitted from graphs for clarity. In panels A-I, each column of graphs represents data from a single type of media, as per column captions. Panels A-F show chromatograms from experiments in which previously purified ChAdOx2 RabG was loaded on Mustang Q Acrodisc, NatriFlo® HD-Q Recon Mini, and CIM-QA 1 mL capsules. In panels A-C. breakthrough was observed and hence dynamic binding capacity was calculated for the Mustang Q and NatriFlo® capsules; breakthrough was not observed after loading 4x10 13 VP on the (larger) CIM-QA column. Panels D-F show the continuations of the above experiments, in which virus was eluted using a linear gradient of increasing conductivity to allow estimation of elution conditions; the conductivity at the peak of virus elution is shown. Panels G-I show chromatograms from experiments in which diafiltered lysate containing ChAdOx2 RabG was loaded on Mustang Q Acrodisc, NatriFlo® HD-Q Recon Mini, and CIM-QA 1 mL capsules, followed by step elution. Panel J presents DBC, virus recovery and HCP reduction data from the experiments shown in Panels A-F. In the case of the CIM-QA column, breakthrough was not reached despite loading 3x10 13 VP on the 1 mL device. Panels K-L show chromatograms from experiments in which previously purified ChAd63 ME-TRAP and ChAdOx1 RVF were loaded on Mustang Q Acrodisc capsules and eluted with a linear conductivity gradient, as above.
Single Use Pressure Sensor Flow Cells, supplied by PendoTECH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/single-use pressure sensor flow cells/product/PendoTECH
Average 90 stars, based on 1 article reviews
single-use pressure sensor flow cells - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Sensirion ag liquid flow sensor sensirion model lg 16-2000
Comparison of anion exchange media. Chromatograms from small-scale anion exchange experiments are shown. In all cases, solid lines indicate A 280 (left axis) and dashed lines indicate <t>conductivity</t> (right axis). A 260 data was also collected, with results paralleling the A 280 data, but is omitted from graphs for clarity. In panels A-I, each column of graphs represents data from a single type of media, as per column captions. Panels A-F show chromatograms from experiments in which previously purified ChAdOx2 RabG was loaded on Mustang Q Acrodisc, NatriFlo® HD-Q Recon Mini, and CIM-QA 1 mL capsules. In panels A-C. breakthrough was observed and hence dynamic binding capacity was calculated for the Mustang Q and NatriFlo® capsules; breakthrough was not observed after loading 4x10 13 VP on the (larger) CIM-QA column. Panels D-F show the continuations of the above experiments, in which virus was eluted using a linear gradient of increasing conductivity to allow estimation of elution conditions; the conductivity at the peak of virus elution is shown. Panels G-I show chromatograms from experiments in which diafiltered lysate containing ChAdOx2 RabG was loaded on Mustang Q Acrodisc, NatriFlo® HD-Q Recon Mini, and CIM-QA 1 mL capsules, followed by step elution. Panel J presents DBC, virus recovery and HCP reduction data from the experiments shown in Panels A-F. In the case of the CIM-QA column, breakthrough was not reached despite loading 3x10 13 VP on the 1 mL device. Panels K-L show chromatograms from experiments in which previously purified ChAd63 ME-TRAP and ChAdOx1 RVF were loaded on Mustang Q Acrodisc capsules and eluted with a linear conductivity gradient, as above.
Liquid Flow Sensor Sensirion Model Lg 16 2000, supplied by Sensirion ag, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/liquid flow sensor sensirion model lg 16-2000/product/Sensirion ag
Average 90 stars, based on 1 article reviews
liquid flow sensor sensirion model lg 16-2000 - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

Image Search Results


Comparison of anion exchange media. Chromatograms from small-scale anion exchange experiments are shown. In all cases, solid lines indicate A 280 (left axis) and dashed lines indicate conductivity (right axis). A 260 data was also collected, with results paralleling the A 280 data, but is omitted from graphs for clarity. In panels A-I, each column of graphs represents data from a single type of media, as per column captions. Panels A-F show chromatograms from experiments in which previously purified ChAdOx2 RabG was loaded on Mustang Q Acrodisc, NatriFlo® HD-Q Recon Mini, and CIM-QA 1 mL capsules. In panels A-C. breakthrough was observed and hence dynamic binding capacity was calculated for the Mustang Q and NatriFlo® capsules; breakthrough was not observed after loading 4x10 13 VP on the (larger) CIM-QA column. Panels D-F show the continuations of the above experiments, in which virus was eluted using a linear gradient of increasing conductivity to allow estimation of elution conditions; the conductivity at the peak of virus elution is shown. Panels G-I show chromatograms from experiments in which diafiltered lysate containing ChAdOx2 RabG was loaded on Mustang Q Acrodisc, NatriFlo® HD-Q Recon Mini, and CIM-QA 1 mL capsules, followed by step elution. Panel J presents DBC, virus recovery and HCP reduction data from the experiments shown in Panels A-F. In the case of the CIM-QA column, breakthrough was not reached despite loading 3x10 13 VP on the 1 mL device. Panels K-L show chromatograms from experiments in which previously purified ChAd63 ME-TRAP and ChAdOx1 RVF were loaded on Mustang Q Acrodisc capsules and eluted with a linear conductivity gradient, as above.

Journal: Vaccine

Article Title: Simian adenovirus vector production for early-phase clinical trials: A simple method applicable to multiple serotypes and using entirely disposable product-contact components

doi: 10.1016/j.vaccine.2019.04.056

Figure Lengend Snippet: Comparison of anion exchange media. Chromatograms from small-scale anion exchange experiments are shown. In all cases, solid lines indicate A 280 (left axis) and dashed lines indicate conductivity (right axis). A 260 data was also collected, with results paralleling the A 280 data, but is omitted from graphs for clarity. In panels A-I, each column of graphs represents data from a single type of media, as per column captions. Panels A-F show chromatograms from experiments in which previously purified ChAdOx2 RabG was loaded on Mustang Q Acrodisc, NatriFlo® HD-Q Recon Mini, and CIM-QA 1 mL capsules. In panels A-C. breakthrough was observed and hence dynamic binding capacity was calculated for the Mustang Q and NatriFlo® capsules; breakthrough was not observed after loading 4x10 13 VP on the (larger) CIM-QA column. Panels D-F show the continuations of the above experiments, in which virus was eluted using a linear gradient of increasing conductivity to allow estimation of elution conditions; the conductivity at the peak of virus elution is shown. Panels G-I show chromatograms from experiments in which diafiltered lysate containing ChAdOx2 RabG was loaded on Mustang Q Acrodisc, NatriFlo® HD-Q Recon Mini, and CIM-QA 1 mL capsules, followed by step elution. Panel J presents DBC, virus recovery and HCP reduction data from the experiments shown in Panels A-F. In the case of the CIM-QA column, breakthrough was not reached despite loading 3x10 13 VP on the 1 mL device. Panels K-L show chromatograms from experiments in which previously purified ChAd63 ME-TRAP and ChAdOx1 RVF were loaded on Mustang Q Acrodisc capsules and eluted with a linear conductivity gradient, as above.

Article Snippet: To ensure that all product-contact components were disposable, single-use liners (Merck) were used with the Pellicon® 2 Mini TFF cassettes, and chromatography monitoring employed single-use pressure, conductivity and UV spectrometry sensor flow cells (Pendotech) (data shown in B).

Techniques: Comparison, Purification, Capsules, Binding Assay, Virus

Downstream process overview and results. Panel A shows an overview of the downstream process steps. Panel B shows conductivity and A 280 traces obtained for at-scale chromatography for each of the three vaccines, as indicated in captions for each plot. In each case, loading occurs over the first ∼ 600 mL (a degree of A 280 deflection from impurity flow-through is visible) and the largest A 280 peak represents the eluted virus which was collected. Note for ChAdOx2 RabG that the pre-elution wash and the post-elution high-salt wash produce relatively small A 280 peaks (predominantly impurity, with some virus, as assessed by SDS-PAGE); this data was obtained using UV and conductivity sensors of the Akta Purifier. For ChAd63 and ChAdOx1, data was obtained using the complete single-use chromatography rig (i.e. with single-use UV and conductivity sensors [Pendotech]) and no post-elution wash was performed. For ChAd63, due to the lower conductivity at which this vaccine eluted, no pre-elution wash was used. Panel C shows samples from each stage of the downstream process on a Coomassie-stained SDS-PAGE gel. Samples shown are from a single process run with the ChAdOx2 RabG vaccine, but are typical of runs with all three investigated vaccines.

Journal: Vaccine

Article Title: Simian adenovirus vector production for early-phase clinical trials: A simple method applicable to multiple serotypes and using entirely disposable product-contact components

doi: 10.1016/j.vaccine.2019.04.056

Figure Lengend Snippet: Downstream process overview and results. Panel A shows an overview of the downstream process steps. Panel B shows conductivity and A 280 traces obtained for at-scale chromatography for each of the three vaccines, as indicated in captions for each plot. In each case, loading occurs over the first ∼ 600 mL (a degree of A 280 deflection from impurity flow-through is visible) and the largest A 280 peak represents the eluted virus which was collected. Note for ChAdOx2 RabG that the pre-elution wash and the post-elution high-salt wash produce relatively small A 280 peaks (predominantly impurity, with some virus, as assessed by SDS-PAGE); this data was obtained using UV and conductivity sensors of the Akta Purifier. For ChAd63 and ChAdOx1, data was obtained using the complete single-use chromatography rig (i.e. with single-use UV and conductivity sensors [Pendotech]) and no post-elution wash was performed. For ChAd63, due to the lower conductivity at which this vaccine eluted, no pre-elution wash was used. Panel C shows samples from each stage of the downstream process on a Coomassie-stained SDS-PAGE gel. Samples shown are from a single process run with the ChAdOx2 RabG vaccine, but are typical of runs with all three investigated vaccines.

Article Snippet: To ensure that all product-contact components were disposable, single-use liners (Merck) were used with the Pellicon® 2 Mini TFF cassettes, and chromatography monitoring employed single-use pressure, conductivity and UV spectrometry sensor flow cells (Pendotech) (data shown in B).

Techniques: Chromatography, Vaccines, Virus, SDS Page, Staining